News | Short Programme | General Catalogue | Starting up Notice | Version Française Worldwide Sites | Search :


You are actually in : BAMO EN » Our Products » General Catalogue » Conductivity » BAMOPHOX 322
Information
News
Workshops Offices
How it runs
Contact Us
Our house
Our History
General Catalogue
pH and ORP 100
Chlorine, disinfection 190
Data processors 200
Conductivity 300
Water hardness 375
Turbidity 400
Oxygen 450
Level 500
Temperature 600
Flow 700
Pressure 800
Plastic Valves 900
Old Documents
Old Docs
Old News
Along the Time
ATEX Products
Des têtes bien faites...
BAMOPHOX 322, RESISTIVITY / CONDUCTIVITY General Catalogue 322-01
Previous Product
Starting up Notice
PDF Version : EN
Next Product









BAMOPHOX 322, RESISTIVITY / CONDUCTIVITY
- µS or MΩ built-in program

- Programmable scales:
0 - 200 Ω up to 0 - 200 MΩ
0 - 2 µS up to 0 - 20 mS
TOR version: 0 - 2 mS up to 0 - 2000 mS

- Convenient probesfactor: 10 - 1 - 0.1 - 0.01
TOR sensor TCS 100

- Temperature compensation
Automatic or manual

- 2 analog outputs 0/4-20mA, galvanic insulated
- 3 relay outputs (Normally open contact)
- 1 input to switch the regulation on Stand-by

- 2 models: Panel mounting 72 x 144 (322E)
Wall mounting IP 65 (322M)

- OPTIONS : RS 422 /J-BUS + LOGGER
Extension for 2nd measurement input

EXTENSION TERMINAL

An extension terminal (wall or panel mounting):

-Allows a second measurement parameter (pH, Conductivity, Chlorine,Turbidity, Flow, and 4-20 mA, depending of the model)

- The data from this blind device are displayed on the main device (second line display). A 4 wires shielded cable is necessary to link both devices (maximum length of 500m)

- The options RS422 and the data logger are shared between bothBAMOPHOX.


DESCRIPTION

The BAMOPHOX 322 offers high flexibility on use mixing different built-inprogrammes for regulation, thresholds, temperature compensation, andalarms. The 2 lines back lighted display, 16 alphanumerical characters,gives an easy measurement and temperature reading in any conditions. Italso displays the configuration menu and settings of thresholds, analogicaloutputs, operation data modes, calibration steps.
To allow a quick and easy diagnostic after configuration a simulation program is built-in with direct actuation on contacts outputs,analogical outputs and PID regulation. A copy of the signal on the 4-20 mA output is galvanic insulated; it can be set up within theall range of the parameter. Temperature measurement is also available on a 4-20 mA output (this output is not available when PIDregulation is in use). Associated probes may have a conductance factor from 0,01 to 10 to get an accurate measurement from 200 ?up to 200 M?or from 2 ?S up to 20 mS.


TECHNICAL FEATURES

Displayed parameters: Measurement values - Configuration Menu - Temperature value

Display: Back lighted - 2 lines of 16 alphanumerical characters ; 9,2 mm high

Indication: LED alarms status

Configuration: 8 push buttons keyboard on front face - Keyword protected

Scales:
322 CE 0...2 µS, 0...20 µS, 0...200 µS, 0...2 mS, 0...20 mS
322 RE 0...200 Ω, 0...2 kΩ, 0...20 kΩ, 0...200 kΩ, 0...2 MΩ, 0...20 MΩ, 0...200 MΩ
322 TOR 0...20 mS, 0...200 mS, 0...2000 mS

Accuracy: ±0,3%, ±0,3°C

Probe input: BNC plug

Temperature compensation:
Automatic with an input for a 3 wires Pt 100 Ohm/0°C, range 0…100°C
Manually from 0…100°C

Relay outputs:
4 closing contacts (Silver alloy), voltage free
Thresholds: 3 programmable independent thresholds - with adjustable hysteresis 0…100% and adjustable timer from 0 to 9999 sec
Output relay: Common alarm signal for system dysfunction:
Contact: Initial resistance 100 mΩ as a maximum (voltage drop 6 V DC 1 A) Rated at 831 V AC / 3 A / 277 V AC ; 90 W / 3 A / 30 V DC Switching capacity (minimum) 100 mA, 5 V DC (depending of switching frequency,ambient conditions, accuracy) Mechanical life time (minimum) 5 x106operations (180 commutation/min) Electrical life time (minimum) 2 x105 (20 comm./min) [3 A, 125 V AC], [3 A, 30 V DC]and 105(evaluated charge) for 3 A, 125 V AC

Measurement output:
0/4-20 mA (maxi 600 ?) proportional to measurement, galvanic insulated

Temperature output:
0/4-20 mA (max 600 ?), scaling 0…100°C, galvanic insulated

Program Testing:
Simulation through the menu on measurement, temperature, and relay outputs

Main power supply: 230 V AC / 50-60 Hz [other on request] - Consumption 10 VA

Models: Panel mounting, IP65, 72 x 144 mm, connections on screw terminal IP40 Cycle average measurement record, with a programmable period,150000 records maxi on MMC (multi media card) / External driver necessary

OPTION (RS 422 + Logger)
Communication: RS422 output, J-BUS link, binary slave mode, 2400 to 9600 bauds
Data Logger:Cycle average measurement record, with a programmable period, 150000 records maxi on MMC (multi media card) / External driver necessary





RESISTIVITY / CONDUCTIVITY
BAMOPHOX 322
General Catalogue
322-01
BAMO Mesures SAS
22, rue de la voie des bans
ZI de la gare
95100 ARGENTEUIL France
Tel : +33 1 30 25 83 20 Fax : +33 1 34 10 16 05
URL : http://www.bamo.fr Email : export@bamo.fr
Siret : 314 055 864 APE : 2651 B Capital : 400 000 Euros
TVA Intra : FR 08 314 055 864


Généré par CARIBASE 3.2.0

Built by CARIMEDIA