| ATEX Products |
 |
| Des têtes bien faites... |
|
|
|
| BF 1200, Conductivity, Resistivity cells |
General Catalogue 361-01 |
BF 1200, Conductivity, Resistivity cells
- Cell constants K = 1 and K = 10 - With Pt 100 Ohm, or without - Mounting PG 13.5 - Stem: glass tube, diameter 12 mm - Sensor elements in platinum |
Conductivity cells BF 1200 are designed for low resistivity or high conductivity measurements with or without compensation of temperature. Used with our conductivity meters or resistivity meters BAMOPHOX 322, they assure accurate measurements on liquids up to 50 mS (20 Ohm). |
Conductivity cells BF 1200 are mounting with a PG 13.5. The stem is in glass of 120 mm long and 12 mm diameter. On site, they need to be installed with holders; different kinds of probe exist: immersion probes and on-line probes. Conductivity cells type 1200 and 1250 use a connector 9054. Conductivity cells type 1205 and 1255 are factory cable built in, with 4 wires and 1 m long.
|
Conductivity cells BF 1200 and 1205 As they are similar in construction to pH electrodes, all our immersion probes and in-line holders are useful for conductivity cells BF 1200 and 1205. Special adaptations exist for conductivity cells BF 1205 due to the cable output.
Conductivity cells 1250 and 1255 Because of their construction, they can only be used with in-line specific probes. Special adaptations exist for conductivity cells BF 1255 due to the cable output. |
Conductivity cells Material of wetted partsStem (120 mm):Glass Gasket: Neoprene O-ring: Nylon Electrodes: Platinum Maximal pressure: 8 bar Maximal temperature: 100°C Process connection: Pg 13.5 Electrical connection1200 and 1250:Connector typical 9054 1205 and 1255: 1 m cable, shielded wires
Probes for conductivity cell BF 1200 Construction details are on the documentation in reference.
In-line flow through cell holder:9222 and 9223 (see page 140-01) – 9240 (see page 140-02) In-line cell holder, collar mounting:9431 and 9432 (see page 141-01) Immersion probe cell holder 9336 (see page 130-01)
In-line holders for conductivity cell BF 1205 As above, all electrical connection in a housing (cast alloy).
In-line holders for conductivity cell BF 1250 and BF 1255
In-line holder 9700, in line flow through cell holder; model 9700 CT for BF1255 with temperature sensor Material: PVC / PPH Maximal pressures:PVC: 13 bar/ PPH: 10 bar Maximal temperatures:PVC: 50°C / PPH: 100°C Connections:PVC and PPH: unions Ø 25
All in-line holders should be mounted in a by-pass with stop valves (in option). |
|
 |
Conductivity, Resistivity cells
BF 1200 |
General Catalogue